Milestone 4. AlarmScheduler is the only AlarmManager writer; one stable
PendingIntent requestCode per dose-time means re-arming replaces and can
never stack (the no-drift invariant is OS-enforced). DoseAlarmReceiver
handles both occurrence and escalation alarms idempotently and always
re-arms the next occurrence before anything else so the chain can't
break. nagCount lives in dose_log so the ~6-nag cap survives reboot.
SCHEDULE_EXACT_ALARM added maxSdk 32 (USE_EXACT_ALARM is 33+ only).
Emulator-verified (API 35): exact alarm armed (window=0,
policy_permission), fired on time, HIGH notification with Tatt/Utsett,
escalation armed +10 min, next day re-armed, Tatt → TAKEN + inventory
10→9 + escalation cancelled, reboot → BootReceiver re-armed everything.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Milestone 2. Medication / DoseTime / DoseLog per the brief's model.
DoseLog.doseTimeId is SET_NULL (schedule edits must not erase adherence
history) while medId CASCADEs; DoseLog.amount is snapshotted at logging
time so later dose changes don't rewrite the record. Inventory decrement
is a single SQL UPDATE clamped at 0 to stay race-free under escalating
notifications. Enums stored as TEXT; schema exported to app/schemas as
the migration baseline.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>